|
Abbott Laboratories
aveirtm vr single chamber ![]() Aveirtm Vr Single Chamber, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/aveirtm+single-chamber+(vr)+leadless+pacemaker+(lp)/chamber+icd+single/pmc12969587-0-1-12 Average 86 stars, based on 1 article reviews
aveirtm vr single chamber - by Bioz Stars,
2026-11
86/100 stars
|
Buy from Supplier |
Image Search Results
Journal: European Heart Journal. Case Reports
Article Title: Chordae tendineae rupture during a helix-fixation leadless pacemaker implantation
doi: 10.1093/ehjcr/ytag090
Figure Lengend Snippet: ( A ) The Aveir™ VR single-chamber leadless pacemaker and leadless pacemaker delivery system. ( B ) Sleeve-out refers to the process in which the protective sleeve covering the leadless pacemaker body is retracted, thereby exposing the leadless pacemaker body. The leadless pacemaker delivery catheter showed bending that was likely caused by accumulated catheter torque and strong backup force (arrows). ( C ) The leadless pacemaker was dislocated from the right ventricular apical septum to the right ventricular outflow tract. ( D ) The leadless pacemaker became fully covered with a protective sleeve. ( E ) Pulling of the leadless pacemaker and delivery catheter resulted in an elongation of the helix. Helix elongation was first observed around the right atrium and tricuspid valve (arrow). ( F ) Complete helix elongation was noted around the right atrium and inferior vena cava (arrows). ( G ) Helix elongation was confirmed.
Article Snippet: The
Techniques: